Infusion accessories

Find the component. Confirm the complete fluid path.

Browse the BQ+ accessories listed in the Diagram Catalog: stopcocks, access valves, transfer components, caps, connectors and precision IV filters. Start with the closest model; BQ+ will confirm the exact configuration and evidence.

BQ Plus SK50 3-way stopcock BQ Plus NFV-L16 needle-free valve BQ Plus ST03 transfer spike BQ Plus AFRM precision filter
Representative accessory families · exact REF review required
19 diagram-catalog references Core accessory range from Diagram Catalog pp.39–43
5 catalog pages Accessories chapter · Diagram Catalog pp.39–43
19 model photos matched Each Diagram Catalog reference now has a single-product visual
REF-specific release Values and availability require confirmation
Flow control and stopcocks

Choose the port arrangement and pressure route.

Start with the number of ways, luer arrangement and intended pressure conditions. Exact pressure and leakage values remain REF-specific.

BQ Plus SK50 3-way stopcock
SK50

3-way stopcock

PC body · PP luer · PE handle

  • 45° click and 360° rotating-luer design
  • Catalog-stated: no leakage under 200 kPa
  • Catalog-stated flow rate: 2,600 mL/10 min
200 units/case Catalog p.39 →
BQ Plus SK46 3-way stopcock
SK46

3-way stopcock

PC body · PC luer · PE handle

  • 360° rotating-luer design
  • Catalog-stated: no leakage under 58 psi
  • Catalog-stated flow rate: 1,600 mL/10 min
200 units/case Catalog p.39 →
BQ Plus SK48 2-way stopcock
SK48

2-way stopcock

PC body · PC luer · PE handle

  • 360° rotating-luer design
  • Catalog-stated: no leakage under 200 kPa
  • Catalog-stated flow rate: 1,600 mL/10 min
200 units/case Catalog p.39 →
BQ Plus HPSK0110 High-pressure 3-way stopcock
HPSK0110

High-pressure 3-way stopcock

On/off handle configuration

  • Catalog-stated: no leakage under 1,000 psi
  • Pressure rating requires current controlled evidence
200 units/case Catalog p.39 →
Access, injection and valves

Compare access behaviour—not appearance alone.

Heparin caps, check valves and needle-free valves use different interfaces and pressure behaviours. Confirm the complete fluid path before selection.

BQ Plus STY09-IR Heparin cap
STY09-IR

Heparin cap

ABS body · rubber septum

  • Transparent male-luer-lock injection-site route
200 units/case Catalog p.40 →
BQ Plus STY13-IR Heparin cap
STY13-IR

Heparin cap

ABS body · rubber septum

  • Yellow housing route
200 units/case Catalog p.40 →
BQ Plus BCV06 Back-check valve
BCV06

Back-check valve

PC body and luer

  • Catalog-stated opening pressure: 2–3 kPa for gravity; 5–6 kPa for pump routes
  • Catalog-stated: no leakage under 200 kPa
  • Catalog-stated flow rate: 1,000 mL/10 min
200 units/case Catalog p.40 →
BQ Plus NFV-L16 Neutral-pressure needle-free valve
NFV-L16

Neutral-pressure needle-free valve

ABS body · PP cover · silicone valve

  • Catalog-stated priming volume: 0.08 mL
  • Catalog-stated: no leakage under 200 kPa
  • Catalog-stated flow rate: 850 mL/10 min
200 units/case Catalog p.40 →
BQ Plus NFV-L17 negative-pressure needle-free valve
NFV-L17

Negative-pressure needle-free valve

PC body · silicone valve

  • Catalog-stated priming volume: 0.13 mL
  • Catalog-stated: no leakage under 200 kPa
  • Catalog-stated flow rate: 1,000 mL/10 min
200 units/case Catalog p.40 →
Transfer, caps and connectors

Identify the connection task first.

Transfer spikes, vial-access routes, protective caps and dispensing connectors are shown as distinct models so buyers can send the closest reference.

BQ Plus ST03 Double-ended transfer spike
ST03

Double-ended transfer spike

ABS body · PE caps

  • Double-ended transfer route
200 units/case Catalog p.41 →
BQ Plus ST04-FLL + NFV-L17 Female-luer spike with NFV connector
ST04-FLL + NFV-L17

Female-luer spike with NFV connector

ABS spike body · needle-free connector

  • Female-luer spike route
200 units/case Catalog p.41 →
BQ Plus UVAD-22 + NFV-L17 Vented female-luer spike with NFV connector
UVAD-22 + NFV-L17

Vented female-luer spike with NFV connector

ABS body · needle-free connector

  • Vented vial-access route
200 units/case Catalog p.41 →
BQ Plus HT167 Tamper-evident cap
HT167

Tamper-evident cap

PP body · PC cover

  • Protective cap for an NFV connection route
200 units/case Catalog p.41 →
BQ Plus HT110 Combi stopper
HT110

Combi stopper

PP

  • Female- and male-luer closure route
200 units/case Catalog p.41 →
BQ Plus DMC-01 Fluid-dispensing connector
DMC-01

Fluid-dispensing connector

PP · female-to-female ends

  • Fluid transfer and dispensing connection route
200 units/case Catalog p.41 →
Precision filtration

Match filter scale, membrane route and porosity to the finished set.

The catalog separates adult, pediatric and baby filter housings, plus a positive-charge route. Public values require the exact filter REF and controlled evidence.

BQ Plus AFRM Adult precision filter
AFRM

Adult precision filter

ABS body · PES/PTFE membrane route · 10 cm² effective filtration area

  • Catalog options: 0.2 µm, 1.2 µm and 5 µm
  • Clear/amber housings; a white-background product photograph is shown
  • Catalog-stated minimum flow rates: >300 / >1,300 / >1,500 mL per 10 min
Case quantity: confirm by REF Catalog p.42 →
BQ Plus KFRM Pediatric precision filter
KFRM

Pediatric precision filter

ABS body · PES/PTFE membrane route · 5 cm² effective filtration area

  • Catalog options: 0.2 µm, 1.2 µm and 5 µm
  • White-background KFRM product detail shown from the matching catalog REF
  • Catalog-stated minimum flow rates: >150 / >900 / >1,300 mL per 10 min
Case quantity: confirm by REF Catalog p.42 →
BQ Plus BFRM Baby precision filter
BFRM

Baby precision filter

ABS body · PES/PTFE membrane route · 1.5 cm² effective filtration area

  • Catalog options: 0.2 µm, 1.2 µm and 5 µm
  • Clear/amber housings; a white-background product photograph is shown
  • Catalog-stated minimum flow rates: >50 / >400 / >550 mL per 10 min
Case quantity: confirm by REF Catalog p.42 →
BQ Plus AFRM-0.2-G-01 positive-charge 0.2 micrometre filter on white background
AFRM-0.2-G-01

Positive-charge 0.2 µm precision filter

ABS body · PES/PTFE membrane route · 10 cm² effective filtration area

  • The catalog describes bacterial-endotoxin adsorption within 96 hours
  • Catalog-stated: no leakage under 300 kPa for 15 seconds
  • Do not publish the adsorption claim without current controlled evidence
Case quantity: confirm by REF Catalog p.43 →
Model-specific release boundary

A catalog match starts selection. It does not finish verification.

BQ+ confirms the chosen accessory inside the intended finished set, operating conditions and destination-market pathway.

Identity & interface Exact model, mating connections, orientation and complete fluid-path position.
Technical evidence Materials, pressure, leakage, flow, priming volume and filtration values under defined methods.
Market status Packaging, sterilization, labeling, registration scope and current availability.